Support articles

When trying to activate a PAK I get an activation error

When trying to activate a PAK I get an activation error - "Server execution failed" - how do I fixe this?Resolution The License Service requires .Net 4 or later to be installed and working correctlyFor Windows 8, 8.1 and Windows Server 2012 .Net 4.5.1 comes as part of the operating system and would just need to be enabled via the "Turn Windows features on or off"For earlier version of Windows this is a separate download from Microsoft websitehttps://www.microsoft.com/en-gb/download/details.aspx?id=17851 
Requires Tekla Maintenance
by Tekla User Assistance Team
0

Tekla License Service software update March 2015

Tekla Structural Designer 2015 Improved application performance when using Server licenses. Improved application performance when using Local USB key locked licenses. Please note: If you are running a 64-bit version of Windows please apply both the 32-bit & the 64-bit version of this patch
by Tekla User Assistance Team
5

Tekla Structural License Service

The Tekla Structural License Service allows you to share and manage your licenses. It also allows users to commute licenses and report on license activity. At the Server Download and run the Tekla Structural License Service installation file Follow the on-screen prompts to install the ‘License Server’ and ‘License Server Manager’ You can now launch the License Server Manager and activate your licenses If you do not have a separate computer which will act as the license server or your computer is not connected to a network then the license server software can be installed on the same computer
by Tekla User Assistance Team
5

Software installation & licensing guide

Please download and read this PDF before commencing an install. It contains information about the various licensing and installation options available.
Requires Tekla Maintenance
by Tekla User Assistance Team
0

Tekla Structural Designer product bulletin September 2016 (PBTSD-1609-1)

Résumé of Issue There is a potentially unconservative error affecting the automatically calculated loads produced by the Wind Wizard for the Eurocode. This only occurs for the following circumstances:  Head code is set to the United Kingdom (Eurocode) or Ireland (Eurocode) The Wind Loadcases option “Structural Factor - Automatically calculate separate cs and cd factors” is set to On A value of structural damping δs is entered that requires interpolation across two charts in fig. NA.9 (the default value of δs = 0.05 is not affected) Occurrence This issue relates to all versions to date since
Requires Tekla Maintenance
by Tekla Structural Designer Global Support
0

Tekla Structural Designer product bulletin July 2016 (PBTSD-1607-02)

Résumé of Issue The issue affects punching shear checks for the Head code EC EN 1992-1-1:2004. Where both transfer moment and shear exist, and the shear value is negative (for example where a column is supported on a transfer slab), a value of magnification factor β < 1.0 can be calculated which can produce an incorrect and un-conservative result for the check. Occurrence This issue relates to all releases of TSD up to and including TSD 2016 Service Pack 1 (version 16.0.1.45).
Requires Tekla Maintenance
by Tekla Structural Designer Global Support