I have a Validation > Model > General > “Invalid effective width” error. Why do I get this and how do I resolve it?

Tekla Structural Designer
Not version-specific
Tekla Structural Designer
Validation-Model-General
Invalid Effective Width
validation
error
Environment
Not environment-specific

Question

I have a Validation > Model > General > “Invalid effective width” error. Why do I get this and how do I resolve it?

 

 

Image
InvalidEffectiveWidth.png

Answer

In the screenshot below two beams have been identified as having an invalid effective width issue.

 

 

Image
InvalidEffectiveWidth1.png

 


Beam 1 is defined as a beam of Construction "Composite beam", however, the slab that is placed on the beam is not a slab of Type "Composite slab" and hence the error. The slab above the composite beam needs to be a composite slab so that the data of the two objects can interact together. Alternatively, the beam needs to be Construction "Non-composite beam".

 

 

Image
InvalidEffectiveWidth3.png

 

 

 

Image
InvalidEffectiveWidth2.png

 


Beam 2 is defined as a beam of Construction "Composite beam", however, there is no slab that is placed on the beam of Type "Composite slab" and hence the error. To resolve this issue, either the beam needs to be changed to a beam of Construction "Non-composite" or a Composite slab needs to be placed in the model.

 