Why can I not see results for lateral loadcases after running a design?
2022
Tekla Structural Designer
2021
Tekla Structural Designer
2020
Tekla Structural Designer
2019i
Tekla Structural Designer
2019
Tekla Structural Designer
2018i
Tekla Structural Designer
2018
Tekla Structural Designer
2023
Tekla Structural Designer
Environment
Not environment-specific
If Non-linear elements (i.e. tension only bracing) exist in your model, then lateral loadcases will not be solved in isolation as part of the design process by default. This is because it can be difficult for the solver to find a solution since there are no other loads to counteract them.
You can change the default behaviour and elect to run the lateral loadcases as part of the design if you wish, by going to the
Design ribbon tab > Options> Analysis page and checking the "Solve lateral loadcases in isolation......" box.
Image