Issue


Why are my wall wind zones reported as Zero?

 
Image
2017_03_30_12_08_321.png

Resolution


In the screenshot below, the Load ribbon > Wind Load group > Wind Wizard... command has defined the Ground level as  -0.5m. Wind is ignored below this value.

 
Image
2017_03_30_12_09_032.png



If we review the Model ribbon > Levels group > Construction Levels command, the levels in the screenshot below are between -6m and 0m.

 
Image
2017_03_30_12_09_463.png


The wind load is only applied beginning at the height of -0.5m as defined in the Wind Wizard.

Hence, the Zero locations are where the model falls below the Ground level of -0.5m where wind is ignored.

 
Image
2017_03_30_12_10_114.png