Tekla Structural Designer product bulletin June 2017 (PBTSD-1706-1)

Last updated November 20, 2017 by Tekla Structural Designer Development Team tekla-product-development-tsd-team-ug@trimble.com

Tekla Structural Designer product bulletin June 2017 (PBTSD-1706-1)

Trimble releases Tekla Structural Designer product bulletin June 2017 (PBTSD-1706-1) which highlights a potentially unconservative issue related to all Head Codes where in some circumstances punching checks applied to walls with automatically reduced perimeters (accounting for the effects of adjacent openings) did not correctly detect the wall axial loading and set VEd equal to zero.